Ethernet Temperature Interface

Ethernet Temperature Interface

T4511

Temperature Ethernet Sensor of T-Line series by Comet Sytem enables monitoring of temerature via net with transmission of alarms and show history of values. Sensor can generate emails with alerts and data files. Sensor can be connected to various SCADA system by different manufacturers and also to Comet System's Data Base software.


Ethernet interface

Ethernet interface

10Base-T/100Base-TX Ethernet interface via standard RJ45 connector. Manual IP address setting or DHCP.

WWW server

WWW server

Measured values accessible via powerful embedded web server. Mobile Web view. Sensor configuration via web. Web Sensor allows user to customize the design of web pages.

History values memory

History values memory

1000 Measured values are stored into history memory according to selected time interval.

History graphs

History graphs

Graphs with history values are accessible via web pages. Modern HTML5 canvas graphic component allows using graphs from thousands of devices Tablets and smartphones supported. All modern web browsers are supported - Firefox, Opera, Chrome or Internet Explorer 9.

History export to CSV

History export to CSV

History values can be exported directly to CSV file (supported by Microsoft Excel).
Timestamps is shown in CSV file.
SNTP time synchronization. CSV file can be downloaded from web pages or periodically send as email attachment.

Email

Email

Warning emails sent when alarm is on. Emails also sent when alarm is off. SMTP authentication supported, (not SSL). Emails with CSV file attachment can be sent at selected intervals.

Modbus TCP protocol

Modbus TCP protocol

Modbus TCP protocol communication supported. Two Modbus clients can be connected to device at one moment.

Actual values via XML

Actual values via XML

XML protocol for actual measured values reading. This protocol is suitable for device integration into 3rd party SCADA systems.

SNMP protocol

SNMP protocol

SNMP protocol enables reading of actual measured values, alarm status, alarm parameters and last 1000 measured values from history table. MIB tables with OID description are available.

SNMP Trap

SNMP Trap

SNMP Trap for IT infrastructure. Web Sensor allows sending Traps to selected Trap receiver server. Traps are sent in case of alarm or at error states.

SOAP protocol

SOAP protocol

Web Sensor allows to send currently measured values via SOAP v1.1 protocol. The device sends values in XML format to the web server. The advantage of this protocol is that communication is initialized by the device side. No port forwarding is necessary.

Syslog protocol

Syslog protocol

Syslog protocol for IT infrastructure monitoring systems. Web Sensors allow sending text message to selected Syslog server. Messages are sent in case of alarm or at error states like unable to send email, unable to deliver SOAP message, etc.

SNTP protocol - time synchronization

SNTP protocol - time synchronization

Time synchronization with SNTP server.


Ethernet Temperature Sensor
Catalog no: T4511
Range:   -200 to +600°C Adjustable.
Accuracy:   ±0.2°C (without temperature probe)
Power:   9-30 Vdc, max. power consumption 1W
LAN connection:   RJ-45 , 10Base-T or 100Base-TX
Communication protocols   WWW, ModbusTCP, SNMPv1, SOAP, XML
     
PDF icon Operation Manual T4511 Sensor
PDF icon MIB Table